ESE New

Early Streamer Emission (Digital) System Designed in accordance with NF C 17 102 : 2011

Cost effective and easy to install

Need a single air terminal to cover a large area. Also, only two down conductor required for every device

Latest Technology

Proven and latest Lightning Protection System

Approved

Approved by Rajuk, PWD, Fire Department  and many more

What is Lightning Protection System?

Lightning is a gigantic electrical spark!

It has been measured Lightning discharges contain from several thousand amps to over 300,000 amps – enough to light half a million 100 watt bulbs!

The function of an external lightning protection system is to intercept, conduct and disperse a lightning strike safely to earth. Without such a system a building’s structure, electronic systems and the people working around or within it are all at risk.

How ESE System Works LPS designed in accordance with NF C 17 102 : 2011

During a storm the ambient electric field may rise to between 10 to 20 kV/m. As soon as the field exceeds a threshold representing the minimum risk of a lightning strike, the ESE lightning terminal is activated. It draws its energy from the ambient electric field the energy required to generate high voltage pulses, creating and propagating an upward leader. No other power sources are required, and no radioactive components are used.
ESEAT_working_Method-Trenspparent

Lightning air terminal range Early Streamer Emission Air Terminal - ESEAT

Calculating protected areas The radius of protection Rp of an OPR is given by French standard NF C 17-102 (September 2011 edition). It depends on the ESEAT efficiency ∆T of the OPR measured in the high voltage laboratory, on the levels of protection I, II, III or IV calculated according to the lightning risk assessment guides or standards (NF C 17-102 annex A or IEC 62305-2, guides UTE C 17-100-2 or UTE C 17-108) and on the height h of the lightning air terminal over the area to be protected (minimum height = 2 m). The protection radius is calculated according to Annex C in French standard NF C 17-102. For OPR 60, limiting the value of ∆T used in the protection radius calculations to 60 µs (limited 60 µs in accordance with the paragraph 5.2.2 of the NF C 17-102 standard).
Calculation of Protection Area_ESEAT_Transparent

ESE Project Works

LPI ESE-60

Bangabondhu Railway Bridge Construction Project (IHI-SMCC-JV)

LPI ESE-60
ABB OPR60

Shasha Denims Ltd.

ABB OPR60
Cirprotec Nimbus60

Square Pharmaceuticals Ltd.

Cirprotec Nimbus60
LPI Cat-ii-G

Sirajganj Passport Office

LPI Cat-ii-G
Cirprotec Nimbus60

Rohingya Camp, Teknaf

Cirprotec Nimbus60
LPI Cat-ii-SS

Residential Project

LPI Cat-ii-SS
Cirprotec Nimbus60

National Telecommunication Monitoring Centre - NTMC

Cirprotec Nimbus60

Our ESE Brands

Largest collection of  ESE brands in Bangladesh

Designed and Manufactured in France
Withstand Current Capacity: 100kA
Warranty: 1 Year

ABB

Designed and Manufactured in France Withstand Current Capacity: 100kA
Warranty: 1 Year
Designed and Manufactured in Spain 
Withstand Current Capacity: 200kAWarranty: 2 Years

Cirprotec

Designed and Manufactured in Spain
Withstand Current Capacity: 200kA
Warranty: 2 Years
Designed and Manufactured in Australia
Withstand Current Capacity: 100kAWarranty: 3 Years

LPI

Designed and Manufactured in Australia Withstand Current Capacity: 100kA
Warranty: 3 Years

FAQs

Comparison between two major methods of LPS

Early Streamer Emission (Digital) LPS

  • Products for different coverage area are available
  • Simple and cost effective
  • Single air-terminal can cover over 300 ft. radius
  • Generally Class II materials are used
  • Regardless building height or size two grounding facility required
  • Recommended for power station, golf field, commercial and residential projects etc.
  • Latest technology

Conventional (Franklin Rod Method) LPS

  • Custom Designed for individual building
  • Require complex engineering to function properly
  • Single air-terminal can cover up to 50 ft. radius
  • Two classes of conductors used: Class I and Class II
  • Depending on building perimeter, two or more grounding facility required
  • Highly recommended for industrial sheds and buildings
  • Traditional and proven technology

Genesis Bangladesh

Engineering for Safer Tomorrow

Info

264/5 (1st Floor), Middle Pirerbag (60ft Road), Mirpur, Dhaka, BD
info@genesisbangladesh.com
+880 1841 542754

Follow Us

Call Us Now